Click 514 Event Logger
INSTALLER QUICK-REFERENCE GUIDE
2
Wire power and communication
If you are using a Click 200 surge protector with the Click 514, power and com-
munication are provided to the Click 514 through the T-bus (see the Click 200
Quick-Reference Guide). If you dont have a Click 200 surge protector, use the
following steps to wire power and communication into the Click 514:
1 Plug a T-bus 5-screw terminal block into the rst T-bus connector.
2 Wire DC power (10–30 V) from the power supply into the rst screw
terminal on the 5-screw terminal block; wire -DC into the second screw terminal.
3 Connect RS-485 communication (+485, -485 and GND) to either the remaining three screw terminals
on the 5-screw terminal block or to the screw terminals in the pluggable screw terminal block on the
top of the Click 514 (see labels for correct wiring).
e Click 514 has three other communication ports.
˽ RJ-11 jack – Connect a jumper cable here for RS-485 communication
˽ DB-9 connector – Connect a straight-through cable here for RS-232 communication
˽ RS-232/RS-485 terminals – On top of device; usually not used
Note. e Click 514 has been specically designed to work with the Acumen DataBridge SDR2-CF device.
e DataBridge can be used to record several gigabytes of data onto a compact ash card on a daily, hourly
or continuous basis.
www.wavetronix.com
801.734.7200
1
Mount the device
e Click 514 mounts over a T-bus for power and communication:
1 If the Click 514 was shipped with the T-bus connector attached, remove
the connector from the module.
2 Snap the connector onto the DIN rail by positioning it over the rail with
the male connector pointing to the right. Hook one arm over the edge of
the DIN rail and press down on the other arm until it snaps into place.
3 Connect the T-bus connector to the rest of the T-bus by sliding them
together until you hear them snap into place.
4 Mount the Click 514 onto the DIN rail: position it properly over the T-
bus connector, hook the lip over the lower edge of the DIN rail, and use
a rocking motion to snap the module into place.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Click 514 Event Logger

Click 514 Event LoggerINSTALLER QUICK-REFERENCE GUIDE2 Wire power and communicationIf you are using a Click 200 surge protector with the Click 514, po

Page 2

3 Use on-device configuration featuresNext, use the device’s conguration features to make sure the Click 514 is wired and working properly. e Click 5

Page 3 - Programming mode

Use Setup mode to congure the logging values and other settings using Click Supervisor.5 Hold the push-button down, then release when the green LED

Page 4 - WX-500-0198